IO-Link sensor/actuator hubs for specialized applications (Silver Line)
IO-Link hubs - flexible and cost-efficient signal bundling – BNI00KK
The BNI LH5-314-S52-Z012, order code BNI00KK, is an IO-Link 1.1.4 hub with COM3 transfer rate (230.4 kBaud), a minimum process data cycle of 2 ms, 12 bytes process data IN and 2 bytes process data OUT. Its COM 1 connection is an M12x1 male, 4-pin, A-coded connector. Eight M12x1 female, 5-pin, A-coded connection slots provide 16 PNP/NPN digital inputs, Type 1 and Type 3, and 16 PNP digital outputs. The inputs and outputs are configurable for PNP, but not for NPN. An extension port and single-channel monitoring are available.
The hub operates at 18...30.2 VDC. The total sensor current is 2 A, the total actuator current is 4 A, and the switching current is 16 x 2 A. Additional functions include vibration, internal temperature and device discovery. Secondary features comprise Basic Statistics, Boot Cycle Counter, Extreme Environment Status, Identification, Logic Blocks, Operating Hours Counter, Signal Delay, Signal Speed Monitor, Switching Counter, Variant Configuration, and Voltage and Current Monitoring. Condition monitoring covers vibration, internal temperature and inclination with installation aid. The die-cast zinc, nickel-plated housing measures 68 x 31.8 x 181.5 mm, operates at -25...60 °C and has IP67 protection when threaded in.
Alternative products
|
|
Alternative
|
Further alternative
|
|
|
|
|
|
|
| BNI LH5-314-S52-Z012 | BNI LH5-314-S52-Z071 | BNI LH5-314-S52-R012 | |
|
280,00 EUR
List price
|
300,00 EUR
List price
|
270,00 EUR
List price
|
|
| Interface | IO-Link 1.1.4 | IO-Link 1.1.4 | IO-Link 1.1.4 |
|---|---|---|---|
| Operating voltage Ub | 18...30.2 VDC | 18...30.2 VDC | 18...30.2 VDC |
| Connection (COM 1) | M12x1-Male, 4-pin, A-coded | M12x1-Female, 4-pin, A-coded | M12x1-Male, 4-pin, A-coded |
| Connection slots | 8x M12x1-Female, 5-pin, A-coded | 8x M12x1-Female, 5-pin, A-coded | 8x M12x1-Female, 5-pin, A-coded |
| Digital inputs | 16x PNP/NPN, Type 1, Type 3 | 16x PNP/NPN, Type 1, Type 3 | 16x PNP/NPN, Type 1, Type 3 |
| Digital outputs | 16x PNP | 16x PNP | 16x PNP |
| Configurable inputs/outputs | PNP: Yes, NPN: No | PNP: Yes, NPN: No | PNP: Yes, NPN: No |
| Extension port | yes | yes | yes |
| Single-channel monitoring | yes | yes | yes |
| Additional function |
Vibration Internal temperature Device discovery |
Vibration Internal temperature Device discovery |
Vibration Internal temperature Device discovery |
| Current sum US, sensor | 2 A | 2 A | 2 A |
| Switching current | 16x 2 A |
12x 2 A 4x 4 A |
16x 2 A |
| Current sum UA, actuator | 4 A | 16 A | 4 A |
| Housing material | Die-cast zinc, nickel-plated | Die-cast zinc, nickel-plated |
PBT GF30 inserts: stainless steel, 1.4404 |
| Dimension | 68 x 31.8 x 181.5 mm | 68 x 31.8 x 181.5 mm | 68 x 38.3 x 183.5 mm |
| Ambient temperature | -25...60 °C | -25...60 °C | -25...60 °C |
| IP rating | IP67, when threaded in | IP67, when threaded in | IP67, when threaded in |
| Transfer rate | COM3 (230.4 kBaud) | COM3 (230.4 kBaud) | COM3 (230.4 kBaud) |
| Process data cycle min. | 2 ms | - | 2 ms |
| Process data IN | 12 bytes | 12 bytes | 12 bytes |
| Process data OUT | 2 bytes | 2 bytes | 2 bytes |
| Secondary features |
Basic Statistics Boot Cycle Counter Device Discovery Extreme Environment Status Identification Logic Blocks Operating Hours Counter Signal Delay Signal Speed Monitor Switching Counter Variant Configuration Voltage and Current Monitoring |
Basic Statistics Boot Cycle Counter Device Discovery Extreme Environment Status Identification Logic Blocks Operating Hours Counter Signal Delay Signal Speed Monitor Switching Counter Variant Configuration Voltage and Current Monitoring |
Basic Statistics Boot Cycle Counter Device Discovery Extreme Environment Status Identification Logic Blocks Operating Hours Counter Signal Delay Signal Speed Monitor Switching Counter Variant Configuration Voltage and Current Monitoring |
| Secondary features for condition monitoring |
Vibration monitoring Internal temperature monitoring Inclination monitoring and installation aid |
Vibration monitoring Internal temperature monitoring Inclination monitoring and installation aid |
Vibration monitoring Internal temperature monitoring Inclination monitoring and installation aid |
| Connection (supply voltage IN) | - | M12x1-Male, 5-pin, L-coded | - |