Cylindrical version for magnetic-field-resistant applications
Alternative products
|
|
Alternative
|
Further alternative
|
|
|
|
|
|
|
| BES M12MI-PSC30A-S04G-W09 | BES M12MI-PSC40A-S04G-W08 | BES M12MI-PSC40A-S04G-W07 | |
|
638,65 DKK
List price
|
600,23 DKK
List price
|
681,32 DKK
List price
|
|
| Dimension | Ø 12 x 65 mm | Ø 12 x 65 mm | Ø 12 x 65 mm |
|---|---|---|---|
| Style Housing | M12x1 | M12x1 | M12x1 |
| Installation | for flush mounting | for flush mounting | for flush mounting |
| Range | 3 mm | 4 mm | 4 mm |
| Switching output | PNP normally open (NO) | PNP normally open (NO) | PNP normally open (NO) |
| Switching frequency | 1500 Hz Measured at 2 mm, 24 V, 100 mA | 2000 Hz | 2000 Hz |
| Housing material | Brass, PTFE coated | Brass, PTFE coated | Brass, PTFE coated |
| Material sensing surface | PBT, PTFE coated | PBT | PBT, PTFE coated |
| Connection | Connector, M12x1-Male, 3-pin | Connector, M12x1-Male, 3-pin | Connector, M12x1-Male, 3-pin |
| Operating voltage Ub | 10...30 VDC | 10...30 VDC | 10...30 VDC |
| Ambient temperature | -30...85 °C | -40...85 °C | -40...85 °C |
| Magnetic field immune | magnetic field immune (AC/DC) | magnetic field immune (AC/DC) | magnetic field immune (AC/DC) |
| IP rating | IP68 | IP68 | IP68 |
| Approval/Conformity |
CE UKCA cULus WEEE |
CE UKCA WEEE cULus |
CE UKCA WEEE cULus |
| Additional features |
Factor 1 Extended temperature range weld-immune (magnetic field 100kA/m) Housing resistant to weld spatter |
Factor 1 Extended temperature range Housing resistant to weld spatter weld-immune (magnetic field 100kA/m) |
Factor 1 Extended temperature range Housing resistant to weld spatter weld-immune (magnetic field 100kA/m) |