Cylindrical version for magnetic-field-resistant applications
Inductive factor 1 sensors – BES05KW
The BES M12MI-PSC80E-S04G-W08 inductive factor 1 sensor has an M12x1 housing with a diameter of 12 mm and a length of 65 mm. It is designed for non-flush installation and provides a range of 8 mm. The sensor has a PNP normally open (NO) switching output with a switching frequency of 2000 Hz. Its operating voltage is 10...30 VDC. Connection is provided via an M12x1-Male, 3-pin connector.
The housing is made of PTFE-coated brass, while the sensing surface is made of PBT. The ambient temperature range is -40...85 °C, with an extended temperature range as an additional feature. The housing is resistant to weld spatter, and the sensor is magnetic field immune (AC/DC) and weld-immune at 100kA/m. The sensor has IP68 protection and carries CE, UKCA, WEEE and cULus approvals.
Alternative products
|
|
Alternative
|
Further alternative
|
|
|
|
|
|
|
| BES M12MI-PSC80E-S04G-W08 | BES M12ME-PSC80E-S04G-W08 | BES M12ML-PSC80E-S04G-W | |
|
76,03 EUR
List price
|
76,03 EUR
List price
|
68,25 EUR
List price
|
|
| Dimension | Ø 12 x 65 mm | Ø 12 x 50 mm | Ø 12 x 65 mm |
|---|---|---|---|
| Style Housing | M12x1 | M12x1 | M12x1 |
| Installation | non-flush | non-flush | non-flush |
| Range | 8 mm | 8 mm | 8 mm |
| Switching output | PNP normally open (NO) | PNP normally open (NO) | PNP normally open (NO) |
| Switching frequency | 2000 Hz | 2000 Hz | 2000 Hz |
| Housing material | Brass, PTFE coated | Brass, PTFE coated | Brass, PTFE coated |
| Material sensing surface | PBT | PBT | LCP/PTFE |
| Connection | Connector, M12x1-Male, 3-pin | Connector, M12x1-Male, 3-pin | Connector, M12x1-Male, 4-pin |
| Operating voltage Ub | 10...30 VDC | 10...30 VDC | 10...30 VDC |
| Ambient temperature | -40...85 °C | -40...85 °C | -25...70 °C |
| Magnetic field immune | magnetic field immune (AC/DC) | magnetic field immune (AC/DC) | magnetic field immune (AC/DC) |
| IP rating | IP68 | IP68 | IP67 |
| Approval/Conformity |
CE UKCA WEEE cULus |
CE UKCA WEEE cULus |
CE UKCA cULus WEEE |
| Additional features |
Factor 1 Extended temperature range Housing resistant to weld spatter weld-immune (magnetic field 100kA/m) |
Factor 1 Extended temperature range Housing resistant to weld spatter weld-immune (magnetic field 100kA/m) |
Factor 1 Weld immune |