Last edited on 2024-01-25

Common Vision Blox (CVB) Image Manager fails to detect the BVS CA-GX camera

Contents
The GigE Vision standard defines a max. detection timeout of 1000 ms. However, Common Vision Blox uses 200 ms as a standard. As soon as you change the Discovery Timeout to 1000 ms in the Advanced Configuration Menu of the Common Vision Blox Management Console, the cameras will be reliably detected.