Electrical wiring of sensors

What you need to know about wiring of sensors

Which output type do you need: PNP or NPN?What is the difference between normally open and normally closed? We will explain it for you.

PNP output (Sourcing output +24 V DC)

PNP output (Sourcing output +24 V DC): The load is connected to the switching output and the common ground (-). This type of output is common in Europe and North America.

PNP output


NPN output (Sinking output 0 V DC)

NPN output (Sinking output 0 V DC): The load is connected to the switching output and the reference point (+). This type of output is common in Asia.

NPN-Ausgang (Senkausgang 0 V DC)


Normally open (NO)

NO = normally open
The sensor turns "on" when an object is detected. This principle is the most commonly used in automation technology.

NO


Normally closed (NC)

NC = normally closed
The sensor turns "off" when an object is detected.

NC


Complementary (NO + NC)

NO + NC = Complementary
The sensor provides both signals. Both outputs are switched when an object is detected.

Energy consumption labeling
Energy consumption labeling

EPREL - European Product Database for Energy Labeling

For all questions concerning commercial topics such as quotations, orders, and delivery times, our inside sales department will be happy to support you: [email protected]

For Aftersales, Technical Support, Applications and
Product Inquiries we will be happy to support you: [email protected]

Feel free to contact us directly by telephone:

Inside Sales 859-727-2200 - press 1
Presales Tech Support 859-727-2200 - press 2
Aftersales Tech Support 859-727-2200 - press 3


Balluff Inc.

8125 Holton Dr.
Florence, KY 41042

Free sample product

In order to add a free sample product to the cart we will need to remove all the normal products from the cart. Are you sure you want to continue