- Magnetostrictive linear position sensors for extreme environments
- Magnetostrictive linear position sensors for industrial hydraulics
- Magnetostrictive linear position sensors in profile housing
- Magnetostrictive position measuring systems for long distances
- Magnetostrictive position measuring systems for mobile hydraulics
- Redundant magnetostrictive linear position sensors
Magnetostrictive linear position sensors for explosive areas
Magnetostrictive sensors
Available in:
33 versions
For use in Ex Zones 0 and 1, Balluff offers pressure-encapsulated BTL magnetostrictive linear position sensors in various rod configurations with various performance profiles. Depending on the application, you receive from us variants for areas that are threatened by gas or by dust. Magnetostrictive linear position sensors that withstand possible explosion hazards are also available for Zone 2.
The housing for the BTL-J-DEXC-TA12 model series is robust and pressure-encapsulated. Its electronics module can be exchanged quickly and easily. This means that these variants meet the requirements set by the oil and gas industries for high reliability and easy service within the Ex zones.
Features
- Suitable for Zones 0, 1, and 2
- Measurement ranges of up to 7620 mm
- Absolute output signal with high resolution of up to 5 µm
- Pressure-rated up to 600 bar
- Range of interfaces available
- Space-saving housing
- Fast commissioning through characteristic curve adjustment
- Many international certifications, such as IECEx, ATEX, and CSA
33 versions
Order code
|
Interface | Measuring length | Mechanical configuration | Ex category | Ambient temperature | Linearity deviation | Application | Actions |
---|---|---|---|---|---|---|---|---|
Profibus | 25...7620 mm | Fastening 3/4" threads |
ATEX: 1G (EPL Ga) ATEX: 2D (EPL Db) IECEx: EPL Ga IECEx: EPL Db |
-40...60 °C | nnnn = 0050…5500: ± 30 µm, nnnn > 5500: ± 0.02% FS | Stainless steel housing | ||
Analog, voltage | 25...7620 mm | Fastening 3/4" threads |
ATEX: 1G (EPL Ga) ATEX: 2D (EPL Db) IECEx: EPL Ga IECEx: EPL Db |
-40...80 °C | nnnn = 0050…0500: ± 50 µm, nnnn = 0501…5500: ± 0.01% FS, nnnn > 5500: ± 0.02% FS | Stainless steel housing | ||
Analog, current | 25...7620 mm | Fastening 3/4" threads |
ATEX: 1G (EPL Ga) ATEX: 2D (EPL Db) IECEx: EPL Ga IECEx: EPL Db |
-40...80 °C | nnnn = 0050…0500: ± 50 µm, nnnn = 0501…5500: ± 0.01% FS, nnnn > 5500: ± 0.02% FS | Stainless steel housing | ||
Digital pulse | 25...5500 mm | Fastening 3/4" threads |
ATEX: 3G (EPL Gc) ATEX: 2D (EPL Db) IECEx: EPL Gc IECEx: EPL Db |
-40...60 °C | ± 50 µm | Hydraulic cylinder | ||
Analog, voltage | 25...5500 mm | Fastening 3/4" threads |
ATEX: 3G (EPL Gc) ATEX: 2D (EPL Db) IECEx: EPL Gc IECEx: EPL Db |
-40...60 °C | nnnn = 0050…0500: ± 50 µm, nnnn = 0501…5500: ± 0.01% FS | Hydraulic cylinder | ||
SSI | 25...5500 mm | Fastening 3/4" threads |
ATEX: 3G (EPL Gc) ATEX: 2D (EPL Db) IECEx: EPL Gc IECEx: EPL Db |
-40...60 °C | d = 1, 2, 3, 7: ± 30µm, d = 4, 5, 6, 8: ± 2 LSB | Hydraulic cylinder | ||
Analog, current | 25...5500 mm | Fastening 3/4" threads |
ATEX: 3G (EPL Gc) ATEX: 2D (EPL Db) IECEx: EPL Gc IECEx: EPL Db |
-40...60 °C | nnnn = 0050…0500: ± 50 µm, nnnn = 0501…5500: ± 0.01% FS | Hydraulic cylinder | ||
Analog, current | 25...7620 mm | Fastening 3/4" threads |
ATEX: 3G (EPL Gc) ATEX: 2D (EPL Db) IECEx: EPL Gc IECEx: EPL Db |
-40...60 °C | nnnn = 0050…0500: ± 200 µm, nnnn > 0500: ± 0.04% FS | Redundant construction | ||
Profibus | 25...7620 mm | Fastening M18 threads |
ATEX: 1G (EPL Ga) ATEX: 2D (EPL Db) IECEx: EPL Ga IECEx: EPL Db |
-40...60 °C | nnnn = 0050…5500: ± 30 µm, nnnn > 5500: ± 0.02% FS | Stainless steel housing | ||
Analog, voltage | 25...7620 mm | Fastening M18 threads |
ATEX: 1G (EPL Ga) ATEX: 2D (EPL Db) IECEx: EPL Ga IECEx: EPL Db |
-40...80 °C | nnnn = 0050…0500: ± 50 µm, nnnn = 0501…5500: ± 0.01% FS, nnnn > 5500: ± 0.02% FS | Stainless steel housing |
Edit columns